Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. We test ambient temperatures at 35c in our environment to greater reflect warmer internal chassis conditions.
We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa)
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA
DC Output Load Regulation
|
||||||||||
Combined DC Load |
+3.3V
|
+5V
|
+12V
|
+5VSB
|
-12V | |||||
A
|
V
|
A
|
V
|
A
|
V
|
A
|
V
|
A | V | |
100W
|
1.55
|
3.36
|
1.78
|
5.02
|
6.69
|
12.08
|
0.50
|
5.01
|
0.20
|
-12.02
|
250W
|
3.42
|
3.35
|
4.45
|
5.01
|
17.16
|
12.07
|
1.00
|
5.01
|
0.30
|
-12.03
|
500W
|
7.07
|
3.35
|
9.15
|
5.01
|
34.67
|
12.07
|
2.00
|
5.00
|
0.50
|
-12.04
|
750W |
11.06
|
3.35
|
13.74
|
5.01
|
52.75
|
12.05
|
2.50
|
5.00
|
0.60
|
-12.03
|
1000W
|
16.86
|
3.34
|
18.96
|
5.00
|
71.94
|
12.01
|
3.00
|
5.00
|
0.80
|
-12.03
|
The load regulation of this power supply is fantastic, with all rails holding close to reference levels.
Super Flower Leadex II 1000W | Maximum Load |
1187W |
We managed to get another 187W from the power supply before the protection circuitry kicked in. The supply was undamaged and it was ready to fire up again when we were a little more sensible with the load.
Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.
Cross Load Testing | +3.3V | +5V | +12V | -12V | +5VSB | |||||
A | V | A | V | A | V | A | V | A | V | |
885W | 2.0 | 3.34 | 2.0 | 5.01 | 72.0 | 12.00 | 0.2 | -12.03 | 0.50 | 5.01 |
240W | 20.0 | 3.34 | 24.0 | 4.98 | 2.0 | 12.07 | 0.2 | -12.02 | 0.50 | 5.01 |
The Super Flower supply handled the Cross load tests without any concerns. Excellent results.
We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.
ATX12V Ver 2.2 Noise/Ripple Tolerance
|
|
Output
|
Ripple (mV p-p)
|
+3.3V
|
50
|
+5V
|
50
|
+12V1
|
120
|
+12V2
|
120
|
-12V
|
120
|
+5VSB
|
50
|
Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.
AC Ripple (mV p-p) | ||||
DC Load | +3.3V | +5V | +12V | 5VSB |
100W | 5 | 5 | 10 | 5 |
250W | 10 | 5 | 10 | 5 |
500W | 10 | 10 | 15 | 5 |
750W | 10 | 10 | 15 | 5 |
1000W | 15 | 10 | 20 | 10 |
Ripple suppression from this unit is extremely impressive indeed with +12V output peaking at 20mV at 100% load. +3.3V and +5V rails hit 15mV and 10mV respectively at full load.
Efficiency (%)
|
|
100W
|
83.4
|
250W
|
92.2
|
500W
|
93.2
|
750W
|
92.0
|
1000W
|
90.4
|
The efficiency results are excellent, peaking at just over 93% at 500W. This drops to 90.4% efficiency at full load. This is well in excess of the 92% industry rating when at 50 percent load. This is certainly an extremely efficient ‘Gold' rated unit.
We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.
Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.
As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.
KitGuru noise guide
10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refridgerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum
Noise (dBA)
|
|
100W
|
28.0
|
250W
|
28.0
|
500W
|
31.6
|
750W
|
34.7
|
1000W | 36.3 |
ECO mode is beneficial in that you can turn the fan off completely under 60c with moderate to lesser loads. We found that at 400 watts or less the fan tended to disable completely. In active mode the fan spins around 800-900 rpm at lower loads, rising as the need demands.
On a slightly negative point I did notice the operational pitch of this fan more than most I have listened to in recent months. This is however subjective and will differ from person to person. I would say however that for those of you with sensitive ears, there are better options from a noise level currently available on the market.
Temperature (c)
|
||
Intake
|
Exhaust
|
|
100W
|
35
|
38
|
250W
|
35
|
43
|
500W
|
38
|
50
|
750W
|
43
|
58
|
1000W
|
46
|
64
|
With the high efficiency of this unit, the temperatures are well maintained throughout the full range of the thermal curve.
Maximum load
|
Efficiency
|
1187W
|
88.8
|
Pushing the PSU above its rated limits generates an efficiency level of around 88.8%. This is not a viable ‘real world’ situation, but its interesting nonetheless.