Home / Tech News / Featured Tech News / Seasonic Prime TX-1600 ATX 3.0 Titanium Review

Seasonic Prime TX-1600 ATX 3.0 Titanium Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. Due to public requests we have changed our temperature settings recently – previously we rated with ambient temperatures at 25C, we have increased ambient temperatures by 10c (to 35c) in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• Extech digital sound level meter
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

12V output is single rail for our testing.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
500W
7.63
3.33
8.82
5.01
36.05
12.02
1.5
5.01
0.30 -12.02
750W
12.63
3.33
14.12
5.01
52.06
12.02
2.0
5.01
0.30 -12.01
1000W
17.75
3.32
20.00
5.01
72.25
12.02
2.5
5.01
0.50 -12.02
1250W 18.84 3.32 24.04 5.00 90.14 12.01 3.0 5.01 0.60 -12.01
1500W
18.87
3.30
22.64
5.00
115.90
12.00
3.5
5.00
0.80 -12.01
1600W 10.00 3.29 10.00 5.01 125.00 12.00 3.5 5.01 0.80 -12.02

Load regulation is stellar, even when delivering the full 1600 watts of power.

Seasonic TX-1600 Titanium PSU Maximum Load
1895W

We managed to get the PSU to achieve 1895W before it would shut down, delivering 295W more than the rated specifications.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
1150W 3.0 3.33 2.0 5.02 92.0 12.00 0.2 -12.03 0.50 5.01
250W 20.0 3.31 24.0 5.01 5.0 12.01 0.2 -12.03 0.50 5.01

The Seasonic TX-1600W Titanium Power Supply produced class leading results in the cross loading test. It exhibited no discernible weaknesses in any of the testing.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum.

ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
500W 5 10 10 15
750W 10 10 10 15
1000W 10 10 15 15
1250W 10 10 15 15
1500W 10 10 15 15
1600W 15 10 20 15

Great ripple suppression results throughout the testing, showcasing how good the design is.

Efficiency (%)
500W
93.83
750W
95.72
1000W
96.21
1250W
95.41
1500W 94.54
1600W 94.29

Overall efficiency is excellent, peaking over 96% at around 50% load.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the power supply we have taken it into our acoustics room environment and have set our Digital Sound Level Noise Decibel Meter Style 2 one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
500W
28.0
750W
28.7
1000W
32.4
1250W
33.3
1500W 35.1
1600W 35.9

The fan in this unit performs well, and even at higher load levels, the pitch is never too intrusive. Under most situations noise levels will be masked by system fans.

Temperature (c)
Intake
Exhaust
500W
36
38
750W
37
43
1000W
42
48
1250W
46
52
1500W
48
53
1600W 50 56

The large fan copes with the heat inside the chassis, spinning more actively as the load increases above 1,000 watts.

Maximum load
Efficiency
1895W
93.85

At 1895W, the efficiency level is still good, measuring 93.85%. Not a practical situation to be running 24/7, but worth noting.

Become a Patron!

Check Also

CD Projekt Red has ‘no plans’ to update Cyberpunk 2077 for PS5 Pro

If you recently invested in a PS5 Pro and had hopes for a Cyberpunk 2077 update, then we have some bad news for you...