Home / Tech News / Featured Tech News / Seasonic Focus GX-1000 V4 (2024) ATX 3 Review

Seasonic Focus GX-1000 V4 (2024) ATX 3 Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 Watt DC load.

We test ambient temperatures at 35c in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa)
• Digital oscilloscope (20M S/s with 12 Bit ADC)

• Variable Autotransformer, 1.4 KVA

We test in a single +12V configuration.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
100W
0.90
3.33
0.90
5.02
7.35
12.03
0.50
5.01
0.20
-12.01
200W
1.60
3.33
1.64
5.02
15.13
12.03
1.00
5.01
0.20
-12.01
500W
3.21
3.33
3.24
5.02
38.60
12.02
1.50
5.00
0.20
-12.02
750W
4.03
3.33
4.17
5.02
58.53
12.02
2.00
5.01
0.30
-12.02
1000W
5.45
3.33
5.51
5.01
78.13
12.00
2.50
5.00
0.30
-12.01

The load regulation of this power supply is excellent across the board.

Seasonic Focus GX-1000 Maximum Load
1148W

The power supply managed to deliver 1148W before shutting down safely.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
885W 2.0 3.33 2.0 5.01 72.0 12.03 0.2 -12.01 0.50 5.01
240W 20.0 3.33 23.0 5.01 2.0 12.03 0.2 -12.01 0.50 5.01

The GX-1000 handled our cross load test very well, holding stable results across the range.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs, the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
100W 4 6 7 4
250W 4 7 7 4
500W 6 9 9 5
750W 8 10 13 6
1000W 10 11 15 7

Ripple noise suppression is superb, with the primary +12V rail peaking at 15mV at full load. Secondary +3.3V and +5V rails both peak around 10mV at full load.

Efficiency (%)
100W
89.2
250W
90.7
500W
93.1
750W
92.0
1000W
90.4

The efficiency results are excellent, peaking at 93% at around 45% load. This drops to around 90.4% efficiency at full load. These are really very positive results for an 80 Plus Gold rated unit.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
100W
<28.0
250W
<28.0
500W
31.8
750W
33.4
1000W 35.2

The fan remains relatively quiet throughout the range, picking up some speed at around 700 Watt load, when it becomes more audible. This new power supply design seems a little quieter than the previous 2023 model.

Temperature (c)
Intake
Exhaust
100W
37
41
250W
38
46
500W
40
50
750W
45
53
1000W
46
58

The fan ramps up in the last 300 Watt of load output, ensuring good airflow across the components. The new OptiSink configuration delivers good results overall.

Maximum load
Efficiency
1148W
88.6

Pushing the PSU above its rated limits generates an efficiency of around 88.4. Not a practical situation in the real world of course. If you need 1145 Watts on a regular basis, you should look at a 1600W unit such as the excellent Seasonic Prime TX-1600 (review HERE) or even the Enermax Revolution D.F.X. 1650W model (review HERE)

Become a Patron!

Check Also

Death Stranding 2 will feature in-game concerts and more

Hideo Kojima has always been a unique director, with the video game creator often experimenting …