Home / Tech News / Featured Tech News / Gamerstorm DQ650-M PSU Review

Gamerstorm DQ650-M PSU Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. We run at 35c in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• Extech digital sound level meter
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

We test in a single +12V configuration.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
65W
0.92
3.38
0.87
5.09
4.40
12.02
0.50
5.02
0.20
-12.03
130W
1.63
3.37
1.65
5.07
9.15
12.00
1.00
5.03
0.20
-12.04
325W
2.90
3.33
3.00
5.05
24.25
11.97
1.50
5.02
0.20
-12.04
490W
4.00
3.35
4.10
5.03
36.92
11.95
2.00
5.01
0.30
-12.03
650W
5.00
3.34
5.30
5.02
49.71
11.92
2.50
5.00
0.30
-12.03

Load regulation is very strong indeed and stable.

Deepcool Gamer Storm DQ650-M PSU Maximum Load
702W

We managed to get the PSU to deliver 702 watts before it would shut down, delivering around 50 watts more than the rated specifications.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
590W 1.0 3.38 1.0 5.02 48.0 11.93 0.2 -12.04 0.50 5.01
145W 12.0 3.32 15.0 4.99 2.0 12.02 0.2 -12.03 0.50 5.02

The unit passed our cross load test without any problems. It was hit with 48A on the +12V rail and it held at 11.93.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
152W 10 10 10 5
270W 15 15 10 10
400W 15 15 15 15
523W 20 20 15 20
650W 20 20 20 25

Ripple suppression proved to be good across the board – passing at all load situations. It held at 20mV at full load across both +3.3 and +5V rails. The +12V rail held well, peaking at 20mV at full load as well. Great results from the CWT partnered supply.

Efficiency (%)
152W
90.3
270W
92.2
400W
91.8
523W
90.4
650W
89.6

Efficiency results are good, peaking at just over 92% around 45% load. At full load efficiency drops to 89.6%. These are solid results for an 80 Plus Gold rated unit.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
152W
<28.0
270W
<28.0
400W
29.7
523W
31.8
650W 33.8

The noise levels emitted from this supply are great. It is truly a very quiet unit under most load situations and only really becomes audible at over 500W load. Even then the fan pitch is not intrusive. Great results.

Temperature (c)
Intake
Exhaust
152W
36
38
270W
39
42
400W
42
46
523W
44
51
650W
47
57

The fan is not very active under lower load situations, spinning very slowly. As the load increases the fan spins a little more actively to compensate for rising temperatures internally.

Maximum load
Efficiency
702 watts
88.7

At 716 watts, the efficiency level measures 88.7%. Not a practical situation to be running 24/7, but worth noting.

Become a Patron!

Check Also

CD Projekt Red has ‘no plans’ to update Cyberpunk 2077 for PS5 Pro

If you recently invested in a PS5 Pro and had hopes for a Cyberpunk 2077 update, then we have some bad news for you...