Home / Tech News / Featured Tech News / Corsair SF1000 Platinum (2024) PSU Review

Corsair SF1000 Platinum (2024) PSU Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load.

We test ambient temperatures at 35c in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa)
• Digital oscilloscope (20M S/s with 12 Bit ADC)

• Variable Autotransformer, 1.4 KVA

We test in a single +12V configuration.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
100W
0.90
3.33
0.90
5.01
7.35
12.04
0.50
5.01
0.20
-12.01
200W
1.60
3.33
1.64
5.01
15.13
12.04
1.00
5.01
0.20
-12.01
500W
3.21
3.33
3.24
5.01
38.60
12.04
1.50
5.01
0.20
-12.01
750W
4.03
3.33
4.17
5.01
58.53
12.03
2.00
5.01
0.30
-12.00
1000W
5.45
3.33
5.51
5.01
78.13
12.02
2.50
5.01
0.30
-12.02

The load regulation of this power supply is superb across the board.

Corsair SF1000 PSU Maximum Load
1111W

The power supply managed to deliver 1111W before shutting down safely.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
885W 2.0 3.33 2.0 5.01 72.0 12.02 0.2 -12.01 0.50 5.01
240W 20.0 3.33 23.0 5.01 2.0 12.03 0.2 -12.01 0.50 5.01

This power supply handled our cross load test very well, holding stable results across the range.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs, the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
100W 13 16 15 17
250W 15 16 22 18
500W 16 18 27 19
750W 18 19 31 23
1000W 21 21 35 25

Noise suppression is not class leading, but pretty good and well within industry rated safe parameters.

Efficiency (%)
100W
89.7
250W
92.5
500W
94.1
750W
92.7
1000W
89.9

The efficiency results are really good, achieving Platinum rated efficiency levels, peaking at just over 94% between 45-55% load, and dropping to around 90% at full load.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the Power Supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
100W
<28.0
250W
<28.0
500W
33.2
750W
36.8
1000W 38.9

The high quality FDB fan is not very noticeable until load hits around 700 Watts demand – then you can hear it ramping up. It is a pretty small fan, so usually noise levels are inherently higher. It's not the quietest unit we have tested, but I would not call noise levels excessive either. Such a small physical footprint always comes with some trade off.

Temperature (c)
Intake
Exhaust
100W
37
41
250W
38
45
500W
40
52
750W
45
57
1000W
46
60

The large fan and high levels of efficiency ensure good airflow across the components and good operating temperatures.

Maximum load
Efficiency
1111W
89.0

Pushing the PSU above its rated limits generates an efficiency of around 89.0. Not a practical situation in the real world of course.

Become a Patron!