Home / Tech News / Featured Tech News / Corsair RM1200x Shift Series PSU Review

Corsair RM1200x Shift Series PSU Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 Watt DC load.

We test ambient temperatures at 35C in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:

• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• Extech digital sound level meter
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
120W
0.90
3.35
0.93
5.04
8.95
12.07
0.50
5.02
0.20
-12.01
240W
1.62
3.35
1.63
5.03
18.45
12.06
1.00
5.01
0.20
-12.02
600W
3.00
3.35
3.11
5.03
46.78
12.03
1.50
5.01
0.30
-12.00
900W
4.01
3.35
4.05
5.03
70.86
11.99
2.00
5.01
0.30
-12.02
1200W
5.02
3.34
5.20
5.03
94.57
11.96
2.50
5.01
0.30
-12.01

Load regulation is really in the top tier, holding within 1%.

Corsair RM1200x Shift Maximum Load
1357 Watts

We managed to get another 157 Watts from the power supply before the protection circuitry kicked in. The supply was undamaged and it was ready to fire up again when we dropped the load to a more realistic level.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
1190W 4.0 3.35 3.0 5.04 88.0 11.98 0.2 -12.02 0.50 5.01
240W 19.0 3.34 22.0 5.01 2.5 12.06 0.2 -12.02 0.50 5.01

The Corsair RM1200x Shift handled our cross load tests without any issues. When hit with 88A, the +12V rail held at 11.98.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum. ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
100W 5 5 10 5
200W 10 10 15 5
400W 10 10 15 5
600W 15 15 20 10
800W 20 15 20 10
1000W 20 20 25 15
1200W 25 20 30 20

Ripple Suppression is very good, peaking at 30mV on the +12V rail at full load. The +3.3V and +5V rails peak at 25mV and 20mV respectively.

Efficiency (%)
100W
88.5
200W
89.0
400W
91.1
600W
92.1
800W
92.0
1000W 91.5
1200W 90.0

The overall efficiency results are excellent, peaking at over 94% between 40-60% load, and dropping to 91.5% at full load.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the power supply we have taken it into our acoustics room environment and have set our SkyTronic DSL 2 Digital Sound Level Meter (6-130dBa) one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
100W
<28.0
200W
<28.0
400W
<28.0
600W
30.5
800W 32.1
1000W 34.0
1200W 37.2

The fan doesn't activate until the load increases and the profile is quite modest until higher loads are demanded. At full load the fan is clearly audible, however when installed inside a system, with other fans in the mix, it would not be that intrusive. There are quieter power supplies on the market, but these results are very good.

Temperature (c)
Intake
Exhaust
100W
35
37
200W
36
41
400W
38
44
650W
43
50
800W
45
54
1000W 47 57
1200W 50 61

Temperatures are well maintained throughout the load range thanks to the overall efficiency of the design and the good airflow from the large FDB fan.

Maximum load
Efficiency (%)
1357W
88.1

Pushing the power supply above its rated limits generates an efficiency level of around 88.1%. Not a realistic situation to be running but interesting nonetheless.

Become a Patron!

Check Also

Intel’s x86S initiative has been abandoned

Intel has officially abandoned its plans for its own-developed x86S specification, a streamlined version of …