Home / Tech News / Featured Tech News / Corsair HX1500i PSU (Platinum) 2022 Review

Corsair HX1500i PSU (Platinum) 2022 Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 watt DC load. Due to public requests we have changed our temperature settings recently – previously we rated with ambient temperatures at 25C, we have increased ambient temperatures by 10c (to 35c) in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• Extech digital sound level meter
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

12V output is single rail for our testing.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
150W
0.90
3.34
0.84
5.04
11.65
12.07
0.5
5.02
0.20 -12.02
300W
1.63
3.34
1.65
5.04
23.75
12.05
1.0
5.01
0.20 -12.02
750W
3.01
3.34
3.02
5.03
59.66
12.02
1.5
5.00
0.30 -12.03
1125W 4.05 3.34 4.05 5.03 90.00 12.00 2.0 5.00 0.30 -12.02
1500W
15.56
3.33
15.55
5.00
113.30
11.97
2.5
4.98
0.50 -12.02

Load regulation is very strong indeed with little fluctuation.

Corsair HX1500i
Maximum Load
1692W

We managed to get the PSU to achieve 1692W before it would shut down, delivering 192W more than the rated specifications. Superb results.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
1150W 3.0 3.34 2.0 5.02 92.0 12.00 0.2 -12.03 0.50 5.01
250W 20.0 3.34 24.0 5.00 5.0 12.04 0.2 -12.02 0.50 5.01

The power supply did very well in our Cross Load tests, indicating a very stable design.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum.

ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs, the cleaner it is (less ripple recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
500W 5 5 10 5
750W 5 5 10 5
1000W 5 10 15 5
1250W 5 10 15 5
1500W 5 10 15 5

Ripple results are class leading, falling well within the top 5% of our overall results in the last 2-3 years of testing.

Efficiency (%)
500W
92.04
750W
92.57
1000W
92.13
1250W
91.45
1500W 90.93

The efficiency ratings are excellent, peaking at around 92.6% and dropping to around 91% at full load.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the power supply we have taken it into our acoustics room environment and have set our Digital Sound Level Noise Decibel Meter Style 2 one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide
10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
500W
<28.0
750W
<28.0
1000W
28.4
1250W
33.7
1500W 37.9

This power supply is very quiet under most load conditions – basically inaudible at up to 900 watts load. Some fan noise is noticed around as demands increase past 1000W. At 1500W, the fan is clearly audible (around 38 dBa) although the low pitch of the fan actually means it is not too intrusive.

Temperature (c)
Intake
Exhaust
500W
36
37
750W
38
39
1000W
41
43
1250W
43
50
1500W
44
53

Due to the high efficiency level of this unit, it never runs hot, even when delivering huge amounts of power.

Maximum load
Efficiency
1692W
89.8

At 1692W, the efficiency level is around 90%.

Become a Patron!