Home / Tech News / Featured Tech News / ASRock Steel Legend SL-850G PSU Review

ASRock Steel Legend SL-850G PSU Review

Correctly testing power supplies is a complex procedure and KitGuru have configured a test bench which can deliver up to a 2,000 Watt DC load. We run at 35c in our environment to greater reflect warmer internal chassis conditions.

We use combinations of the following hardware:
• SunMoon SM-268
• CSI3710A Programmable DC load (+3.3V and +5V outputs)
• CSI3711A Programmable DC load (+12V1, +12V2, +12V3, and +12V4)
• Extech Power Analyzer
• Extech MultiMaster MM570 digital multimeter
• Extech digital sound level meter
• Digital oscilloscope (20M S/s with 12 Bit ADC)
• Variable Autotransformer, 1.4 KVA

We test in a single +12V configuration.

DC Output Load Regulation

Combined

DC Load

+3.3V
+5V
+12V
+5VSB
-12V
A
V
A
V
A
V
A
V
A V
85W
0.95
3.33
0.92
5.02
6.00
12.04
0.50
5.01
0.20 -12.00
170W
1.70
3.33
1.67
5.02
12.35
12.04
1.00
5.01
0.20 -12.01
425W
3.00
3.33
3.05
5.02
32.20
12.02
1.50
5.01
0.30 -12.01
640W 4.05 3.33 4.05 5.01 49.00 12.00 2.00 5.01 0.30 -12.00
850W
5.00
3.33
5.23
5.02
65.52
11.98
2.50
5.01
0.50 -12.01

Load regulation is really good on all the rails.

Next we want to try Cross Loading. This basically means loads which are not balanced. If a PC for instance needs 500W on the +12V outputs but something like 30W via the combined 3.3V and +5V outputs then the voltage regulation can fluctuate badly.

Cross Load Testing +3.3V +5V +12V -12V +5VSB
A V A V A V A V A V
760W 1.0 3.33 1.0 5.02 60.0 11.99 0.2 -12.01 0.50 5.01
165W 15.0 3.32 18.0 5.01 2.0 12.03 0.2 -12.01 0.50 5.01

The power supply dealt with the demanding cross load test without any major concerns.

We then used an oscilloscope to measure AC ripple and noise present on the DC outputs. We set the oscilloscope time base to check for AC ripple at both high and low ends of the spectrum.

ATX12V V2.2 specification for DC output ripple and noise is defined in the ATX 12V power supply design guide.

ATX12V Ver 2.2 Noise/Ripple Tolerance
Output
Ripple (mV p-p)
+3.3V
50
+5V
50
+12V1
120
+12V2
120
-12V
120
+5VSB
50

Obviously when measuring AC noise and ripple on the DC outputs the cleaner (less recorded) means we have a better end result. We measured this AC signal amplitude to see how closely the unit complied with the ATX standard.

AC Ripple (mV p-p)
DC Load +3.3V +5V +12V 5VSB
100W 13 13 20 13
225W 15 15 24 15
450W 16 16 31 17
675W 17 16 37 17
850W 19 17 46 18

Noise suppression is pretty good across the minor rails. The +12V rail peaks at around 45mV which is well within industry rated tolerances. Not the greatest we have seen in 2024, but perfectly acceptable.

Efficiency (%) 240V
100W
90.3
225W
92.8
450W
93.6
675W
92.7
850W 91.0

The efficiency results are really good, peaking at around 93.6% between 45-55% load, and dropping to around 91% at full load. A strong set of results.

We take the issue of noise very seriously at KitGuru and this is why we have built a special home brew system as a reference point when we test noise levels of various components. Why do this? Well this means we can eliminate secondary noise pollution in the test room and concentrate on components we are testing. It also brings us slightly closer to industry standards, such as DIN 45635.

Today to test the power supply we have taken it into our acoustics room environment and have set our Digital Sound Level Noise Decibel Meter Style 2 one meter away from the unit. We have no other fans running so we can effectively measure just the noise from the unit itself.

As this can be a little confusing for people, here are various dBa ratings in with real world situations to help describe the various levels.

KitGuru noise guide

10dBA – Normal Breathing/Rustling Leaves
20-25dBA – Whisper
30dBA – High Quality Computer fan
40dBA – A Bubbling Brook, or a Refrigerator
50dBA – Normal Conversation
60dBA – Laughter
70dBA – Vacuum Cleaner or Hairdryer
80dBA – City Traffic or a Garbage Disposal
90dBA – Motorcycle or Lawnmower
100dBA – MP3 Player at maximum output
110dBA – Orchestra
120dBA – Front row rock concert/Jet Engine
130dBA – Threshold of Pain
140dBA – Military Jet takeoff/Gunshot (close range)
160dBA – Instant Perforation of eardrum

Noise (dBA)
100W
<28
225W
<28
450W
29.7
675W
31.2
850W 37.3

The fan remains disabled at lower loads and it only kicks into action in our environment around 400W-450W load. At usual loads of around 500W-600W the fan is pretty quiet and it is only in the last 10% of load that it ramps up and is clearly audible.

Temperature (c)
Intake
Exhaust
100W
37
42
225W
38
43
450W
40
48
675W
45
54
850W
46
58

Temperatures inside the chassis remain cool even at higher load levels.

Become a Patron!

Check Also

Cyberpunk 2077 has sold 30M copies, Phantom Liberty at 8M

CD Projekt Red's Cyberpunk 2077 has defied its rocky launch to become a major success story, surpassing 30 million copies sold. Phantom Liberty also a hit.